Scope of annex
This annex covers frequency bands and regulatory as well as informative parameters recommended for SRD radiodetermination applications including Equipment for Detecting Movement and Alert. Radiodetermination is defined as the determination of the position, velocity and/or other characteristics of an object, or the obtaining of information relating to these parameters, by means of the propagation properties of radio waves.
Radiodetermination equipment typically conducts measurements to obtain such characteristics. Any kind of point-to-point or point-to-multipoint radio communications is outside of this definition.
Frequency Band | Power / Magnetic Field | Spectrum access and mitigation requirements | Modulation /occupied bandwidth | ECC/ERC Deliverable | Notes | |
---|---|---|---|---|---|---|
n1 | 100Hz - 148kHz |
46 dBµA/m at 10 m distance at 100 Hz outside the NMR device | No requirement | Not specified | For enclosed Nuclear Magnetic Resonance (NMR) applications. Magnetic field strength descending 10dB/decade above 100 Hz | |
n2 | 148kHz - 5000kHz |
-15 dBµA/m at 10 m distance outside the NMR device | No requirement | Not specified | For enclosed Nuclear Magnetic Resonance (NMR) applications | |
n3 | 5000kHz - 30MHz |
-5 dBµA/m at 10 m distance outside the NMR device | No requirement | Not specified | For enclosed Nuclear Magnetic Resonance (NMR) applications | |
n4 | 30MHz - 130MHz |
-36 dBm e.r.p. outside the NMR device | No requirement | Not specified | For enclosed Nuclear Magnetic Resonance (NMR) applications | |
a | 30MHz - 12.4GHz |
* | * | * | ECC/DEC/(06)08 | For Ground- and Wall- Probing Radar (GPR/WPR) imaging systems, subject to an appropriate licensing regime. * See detailed requirements in related ECC Decision |
b | 2200MHz - 8000MHz |
* | * | * | ECC/DEC/(07)01 | For Material Sensing Devices. * See detailed requirements in related ECC Decision |
c | 2400MHz - 2483.5MHz |
25 mW e.i.r.p. | No requirement | Not specified | ||
d | 3100MHz - 4800MHz |
* | * | * | ECC/REC/(11)09 | For UWB Location Tracking Systems Type 2 (LT2), subject to an appropriate licensing regime. * See detailed requirements in related ECC Recommendation |
e | 3100MHz - 4800MHz |
* | * | * | ECC/REC/(11)10 | For UWB Location tracking application for emergency and disaster situations (LAES), subject to an appropriate licensing regime. * See detailed requirements in related ECC Recommendation |
f1 | 4500MHz - 7000MHz |
-41.3 dBm/MHz e.i.r.p. outside the enclosed test tank structure | No requirement | Not specified | For Tank Level Probing Radar (TLPR) | |
g1 | 6000MHz - 8500MHz |
* | * | Not specified | ECC/DEC/(11)02 | For Industrial Level Probing Radar (LPR). *See detailed requirements in related ECC Decision |
f2 | 8500MHz - 10.6GHz |
-41.3 dBm/MHz e.i.r.p. outside the enclosed test tank structure | No requirement | Not specified | For Tank Level Probing Radar (TLPR). The radiated unwanted emissions within the frequency band 10.6-10.7 GHz outside the test tank enclosure shall be less than -60 dBm/MHz e.i.r.p. | |
h | 9200MHz - 9500MHz |
25 mW e.i.r.p. | No requirement | Not specified | ||
i | 9500MHz - 9975MHz |
25 mW e.i.r.p. | No requirement | Not specified | ||
j | 10.5GHz - 10.6GHz |
500 mW e.i.r.p. | No requirement | Not specified | ||
k | 13.4GHz - 14GHz |
25 mW e.i.r.p. | No requirement | Not specified | ||
l | 17.1GHz - 17.3GHz |
26 dBm e.i.r.p. | DAA | Not specified | For Ground Based Synthetic Aperture Radar (GBSAR). Specific requirements for the radar antenna pattern and for the implementation of Detect And Avoid (DAA) technique apply as described in EN 300 440 | |
m | 24.05GHz - 24.25GHz |
100 mW e.i.r.p. | No requirement | Not specified | The frequency band 24.0-24.25 GHz is identified with the same emission parameters in Annex 1 band m | |
g2 | 24.05GHz - 26.5GHz |
* | * | Not specified | ECC/DEC/(11)02 | For Industrial Level Probing Radar (LPR). *See detailed requirements in related ECC Decision |
f3 | 24.05GHz - 27GHz |
-41.3 dBm/MHz e.i.r.p. outside the enclosed test tank structure | No requirement | Not specified | For Tank Level Probing Radar (TLPR) | |
g3 | 57GHz - 64GHz |
* | * | Not specified | ECC/DEC/(11)02 | For Industrial Level Probing Radar (LPR). *See detailed requirements in related ECC Decision |
f4 | 57GHz - 64GHz |
-41.3 dBm/MHz e.i.r.p. outside the enclosed test tank structure | No requirement | Not specified | For Tank Level Probing Radar (TLPR) | |
q | 69.8GHz - 79.9GHz |
7 dBm e.i.r.p. | No requirement | Not specified | For security scanners operated indoors | |
g4 | 75GHz - 85GHz |
* | * | Not specified | ECC/DEC/(11)02 | For Industrial Level Probing Radar (LPR). *See detailed requirements in related ECC Decision |
f5 | 75GHz - 85GHz |
-41.3 dBm/MHz e.i.r.p. outside the enclosed test tank structure | No requirement | Not specified | For Tank Level Probing Radar (TLPR) | |
o | 76GHz - 77GHz |
* | * | * | ECC/DEC/(21)02 | For High Definition Ground Based Synthetic Aperture Radar (HD-GBSAR) Use is not possible in specific areas of some European countries due to exclusion zones implementation around RAS observatories in case of free line of sight. RAS exclusion zones and DAA are required only in case of outdoor use of HD-GBSAR. * See detailed requirements in related ECC Decision |
r | 76.5GHz - 80.5GHz |
19 dBm peak e.i.r.p. (Note 1) | No requirement | Not specified | For security scanners operated indoors | |
p | 116GHz - 260GHz |
* | * | * | ECC/DEC/(22)03 | For specific radiodetermination applications as Generic indoor surveillance radar, Radiodetermination systems for industry automation (RDI), Level probing radar (LPR), Contour determination and acquisition radar (CDR), Tank level probing radar (TLPR), Exterior vehicular radar (EVR), In-cabin vehicular radar (IVR) and Radiodetermination systems for industry automation in shielded environments (RDI-S). * See detailed requirements in related ECC Decision |
Note 1 | At least 23 dB out-of-band attenuation relative to the maximum allowed peak e.i.r.p. is required. |
Harmonised Standards
EN 302 066 sub-band a)
EN 302 065 sub-bands b), d), e)
EN 300 440 sub-bands c), h), i), j), k), m)
EN 302 372 sub-bands f1), f2), f3), f4), f5)
EN 302 729 sub-bands g1), g2), g3), g4)
To be defined sub-bands n1) to n4)
EN 303 661 sub-bands l), o)
To be defined sub-band q)
To be defined sub-band r)
EN 305 550 sub-band p)
Technical parameters also referred to in the
harmonised standard
No information
Frequency issues
Sub-bands n1) to n4):
Enclosed NMR sensors are devices where the material/object under investigation is put inside the enclosure of the NMR device.
NMR techniques use nuclear magnetic resonance excitation and magnetic field strength response of a material/object under test to get information about material properties based on resonance frequency responses of isotopes of atoms. Nuclear magnetic resonance imaging and magnetic resonance tomography systems are not included in this scope.